Variable Speed to RIO, DH+ or Modbus


Serial communications to adjustable speed drives is a concept that can save many dollars in engineering, manufacturing, installation, start-up, and troubleshooting costs; however, developing the actual interface between drives and a PLC can be a prohibitive task, particularly on a one-time basis. The SCIP-U is designed to simplify this problem.

Now, interfacing the Siemens SIMOREG
© DC and SIMOVERT P© AC drives to Allen-Bradley and Modicon programmable controllers is as simple as adding any other device to their remote data links. The SCIP-U performs the complex protocol conversions, remaining transparent to the programmer or operator.

All of the Advantages:
The SCIP-U provides a multi-drop RS485 bus interface to up to 31 Siemens adjustable speed drives. The serial interface is full-functioning, including:

  • Full control of drive parameter values... to monitor or change them
  • Control of normal drive functions, such as Run, Stop, Jog, and Speed
  • Operating status monitoring, and reporting of fault codes
  • Additional control features, including remote fault reset, M.O.P. or torque control, dependent on the specific drive and configuration

    None of the Disadvantages:
  • No custom communication drivers required
  • No complex, custom software is needed
  • No controllers that are unfamiliar to your maintenance people

    RS485 Protocols Supported:
    Simple Protocol
  • 10 word telegram length
  • to 38.4 KBaud
    DUST 6B Protocol
  • Selectable telegram length
  • 117.6 KBaud
    USS Protocol
  • Variable telegram length
  • to 187.5 KBaud

    Specifications:
  • Interfaces  
    Channel A: Synchronous; SDLC Transformer-coupled  
    Channel B: Asynchronous; RS232C/RS422/RS485  

    Physical Dimensions
    Size: 7.5" D x 5.5" W x 1.5" H
    (190mm x 140mm x 38mm)
    Weight: 2.2lbs (1kg.)
    Load: 10 VA
    Power: 115/230 VAC (+/- 25%); 50/60 Hz;
    5 Watts DC: 10 - 35 VDC; 5 Watts

    Installation
    Freestanding; Metal enclosure

    Environment
    Operating: +32 F to 122 F (0 C to +50 C)
    Storage: -40 F to +185 F (-40 C to +85 C)
    Humidity: 5% to 95% non-condensing

    Protocols
    Channel A: A-B DH+ / RIO Link / Modicon
    Modbus+ (via Modbus)
    Channel B: Simple, DUST 6B, USS Protocols

    Configuration
    PC program software menu for communications
    parameters
    Selection
    Jumpers select supply voltage and serial
    interface type

    Indicators
    1 LED for power-on; 5 LEDs for
    communications activity

    Switches
    Reset and Configure/Diagnostics mode pushbuttons

    Error Detection
    Channel A: CRC
    Channel B & C: BCC or CRC

    Communications
    Channel A: Synchronous, DH+ to
    115.2 Kbaud; RIO to 230.4 Kbaud
    Channel B: Asynchronous; 300 Kbaud to
    230.4 Kbaud
    Channel C: ****????

    Hardware
    Z180 Processor; 32 Kbyte socketed EPROM;
    32 Kbyte RAM; 256 byte EEPROM;  
    1 DH+ and 2 serial interface connectors