dl 3500 - DH+ Data Highway Plus

DH+ and DH-485
Product Index

Products

DataLink DL4500 Controller
:
Mod TCP and Ethernet TCP/IP Interface to AB's DH+ and DH-485.

DataLink DL4000 Controller: Serial (DF1, Modbus, ASCII and custom) Interfaces to other DF1, Modbus, and ASCII Serial Devices.

DataLink DL3500 Controller: Latest platform with USB & Serial Interface (DF1, Modbus & ASCII) to Allen-Bradley's DH+, DH-485, Remote I/O, Modicon Modbus and other protocols. Highlights include Palm-sized, DIN Rail, DC Power option, DH+ at 230.4Kb.

DataLink DL3000 Controller
: Serial Interface (DF1, Modbus & ASCII) to Allen-Bradley's DH+ / Remote I/O, Modicon Modbus and other protocols. Highlights include Palm-sized, DIN Rail, DC Power option, DH+ at 230.4Kb.

DataLink Interface Cards
: DL-PC, DL-PCI, DL-PC/104 Interface to Allen-Bradley's DH+, DH-485, Remote I/O, Modicon Modbus and other protocols.

DataLink Custom DL2000 Controller
: Interface OEM equipment connectivity to Allen-Bradley's Data Highway Plus, Remote I/O, Modicon Modbus, etc. (all custom protocols available in DL3000 platform now).

DataLink DL2000 Controller
: Legacy controller still available.


New Products:
DL3500-DH+/IAP - Ethernet IP to Allen Bradley DH+/DH-485
DL4500-MEDH+ - Modbus TCP/IP Network to Allen Bradley’s DH+
DL4500-MEDH-485 - Modbus TCP/IP to Allen Bradley's DH-485


Complete Product List:

DL4500-EDH+ (Ethernet TCP/IP DH+) - DF1 serial driver Gateway to AB's DH+ network via TCP/IP

DL4500-EDH-485 (Ethernet TCP/IP DH-485) - DF1 serial driver Gateway to AB DH485 network via TCP/IP protocol.

DL4500-MEDH+ (Modbus TCP/IP) - Modbus TCP Bridge to Allen-Bradley's (DH+) Datahighway Plus

DL4500-MEDH-485 - Modbus TCP Bridge to communicate to devices on Allen Bradley's DH-485

DL3500-DH+ Ascii (Ascii DH+) - DL3500 - RS232/422/485 and USB Interface to A-B's DH+ or DH485. Interfaces Serial ASCII devices (Scanners/Printers) to A-B's DH+ or DH-485 network. (DH+ Ascii)

DL3500-DH-485 Ascii - DL3500 - RS232/422/485 and USB Interface to A-B's DH+ or DH-485. Interfaces Serial ASCII devices (Scanners/Printers) to A-B's DH+ or DH-485 network.

DL3500-DH+/DF1 (DF1 DH+) - Allows DF1 serial equipment to communicate over Allen-Bradley's DH+ network. (DH+ DF1) (SLC 5/05 DH+).

DL3500-DH-485/DF1 (DF1 DH-485) - Allows DF1 serial equipment to communicate over Allen Bradleys DH-485 network. (DH-485 DF1)

DL3500-DH+ (Bridge DH+ (Data Highway Plus) and DH485 - Lightweight, Din Rail Mounted, DC or USB Powered lower cost alternative to A-B's 1770-KF2 for DH+ or 1770-KF3 for DH-485. Current Protcols are AB DF1, Modicon Modbus, and serial ASCII. The DL3500 can be easily customized to allow any serial protocol access to A-B's DH+ or DH-485. (AB 1770-KF2 replacement or AB 1770-KF3 replacement)

DL3500-DH-485 (ASCII DH-485) - Lightweight, Din Rail Mounted, DC or USB Powered lower cost alternative to AB 1770-KF2 for DH+ or 1770-KF3 for DH-485. Current Protocols are A-B DF1, Modicon Modbus, and serial ASCII. The DL3500 can be easily customized to allow any serial protocol access to AB's DH+ (Data Highway Plus) or AB DH-485. (AB 1770-KF2 replacement or AB 1770-KF3 replacement)

DL3500-DH+/Modbus (Modbus DH+) - Interfaces Modbus Master or Slave devices to Allen-Bradley DH+ network

DL3500-DH-485/Modbus (Modbus DH-485) - Interfaces Modbus Master or Slave devices to A-B's DH-485 network

DL3500-SLC5/04 Bridge - (DH+ DH-485 SLC 5/04) - gives DF1 serial drivers (RSLINX) a DH+ interface for your DH-485 device connected to the CH0 of a SLC 5/04; bridges DH+ to DH-485 using the SLC 5/04 with DH-485 Pass Thru enabled

DH+ RIO Network - Connect your PC's and MMI's via the Plug and Play PCI bus using existing AB DF1 Com Port drivers to A-B's DH+/DH-485 It is a lower cost alternative to A-B's 1784-PKTX card and SST's 5136-SD-PCI

DH-485 Network - Connect your PC's and MMI's via the Plug and Play PCI bus using existing AB DF1 Com Port drivers to A-B's DH+/DH-485 It is a lower cost alternative to A-B's 1784-PKTX card and SST's 5136-SD-PCI

DL-PC (ISA Bus Card Interfaces PCs to A-B Networks) - Data Highway Plus (DH+) / Remote I/O (RI/O) Adapter PC ISA BUS Interface Card DL-PC/104 - Data Highway Plus (DH+) / Remote I/O (RI/O) Adapter PC/104 Interface Card

DL-PCI (Bus Card Interfaces PCs to DH+, DH-485, RIO) - Data Highway Plus (DH+) / Remote I/O (RI/O) Adapter / DH-485 PC PCI BUS Interface Card

DL-STD32 (DH+ OEM) - Connect your OEM equipment and MMI's via the STD32 bus to AB DH+. The DL-STD32 uses the same technology as the DL-PC to use existing RS232 serial DF1 drivers. It is a low cost alternative to the Prolog 7154A interface card. (OEM DH+)

DL2000-ASM (DH+ Printer) Interfaces Serial ASCII devices (Scanners/Printers) to A-B's DH+ protocol

DL2000-INV2 - Interfaces up to 31 Toshiba G2 and G3 inverters to A-B DH+, RIO and Modbus. DL2000-KFX - Allows DF1 serial equipment to communicate over Allen Bradleys DH+

DL2000-PML - Interfaces up to 10 Power Measurements 3720 ACM meters to A-B RIO.

DL2000-RAS (Scanner RIO) - Interfaces Serial ASCII outputting devices (Scanners) to A-B's RIO protocol

DL2000-SCIPU (Variable Speed to RIO, DH+ or Modbus) - Interfaces up to 31 Siemens VS/VF drives to A-B DH+, RIO and Modbus.

DL4000-DAS (Interface bi-directional ASCII to DF1) - Interfaces Serial ASCII devices (Scanners/Printers) to A-B's DF1 protocol

DL4000-DFX (DF1 Port Expander) - allows three DF1 serial devices to simultaneously communicate with each other

DL4000-DMX (DF1 to Modbus MASTER/SLAVE Interface) - Interfaces Modbus Master or Slave devices to AB DF1 protocol

DL4000-MAS (Interface Modbus RTU Master to ASCII) - Interfaces an ASCII Floating Point format number devices to a Modbus Slave RTU

DL4000-MMX (Modbus MASTER RTU to Modbus SLAVE ASCII Interface) - Allows Modbus RTU devices to communicate with multiple Modbus ASCII devices

DL4000-PM (AB Power Monitor 3000 to Modbus) - Provides a DF1 Half Duplex Master interface to A-B's Power Monitor 3000 then sends the converted data via Modbus to a specified Slave RTU devices